MAIN SWITCHBOARD (MSB)

According to requirement of project, full automation or manuel.
Low voltage switch boards up to 1000V.
Generator protections, Load depending start stop, load shedding, auto synchronizing, load sharing, blackout start, KVAR sharing.
Certified from breaker to cable tie.
Special design to different combination of generators.
PTO/PTI combinations.
Variable revolution shaft alternator system.
Tailor made solutions.
Copper and coated busbar.


WHEEL HOUSE & ECR CONSOLES

Tailor made console design for every type of vessel.
2 mm galvanized steel construction.
Easily reachable device locations.
Well marked terminal design.
Illuminating inside.
Large scale color alternatives.
Special offshore, DP, fishing vessel variations.
IP 22 protection ratio.
Navigation consoles
ECR consoles
Cargo control consoles.
Wing consoles.
Radar and Ceilling consoles.
Valve control consoles.


DISTRIBUTION BOARDS

440/400V, 220/110V, 24V AC and DC source.
Insulated from live conductors.
Cleared identify
Covered class rules.
Well know electrical units.
Special design for GMDSS.
Insulation fault system for 24V DC cabinets.
Consumption and voltage indicator.


MOTOR CONTROL CENTERS & STARTER PANELS

Up to 690 V motors.
Direct, star delta, soft starter, auto transformer and frequency converter.
Auto start or remote start function.
Efficiency mode selection. working only according to demand.
Withdrawable chassis design according to customer request.
External and internal fault indication.
Remote control opportunities.
High protection for high current , and short circuit current.
According to demands other protection requirements.


BOW THRUSTER SYSTEM & CONTROL PANEL.

Every Control Voltage level.
With or Without class requirement.
Certified Frequent control device with VACON controller.
Climate control cabinets.
Very low harmonic distortions.
Programmable user friendly design.
Multiple Console panel.
Suitable for Dynamic Position system.
22 kW to 100 kW tested model.
More than 100 kW need to design.
Only Control system can be provided.


AUTOMATION SYSTEM

Scada system design for requirements
Alarm monitoring system design for under 500 gtn, manned vessels
Fan monitoring system for live fish carriers
Yacht control system, include valve, MSB, pumps and alarms
Redundancy for CPU 
Galvanized protected I/O modules
Phoenix or similar type of controllers
Distributed I/O sistem can be possible
Crane automation system experience
Can be programmable for alarm system up to 8 input to 624 input


TRANSFORMER ( LIGHTING & SHORE CONNECTION )

Lighting and shore connection purpose.
Up to 100 kW.
Very few voltage drop at maximum loads.
Not needed forced cooling.
Oven dried varnish.
IP 23 or more for demand.
Full isolated primer and seconder.
Variand voltage level according to customer requirement.


LIGHT COLOUMN SYSTEM

Redundant power supply.
Customized symbol selection.
Up to 1 to 9 coulomb selection.
Power failure and for automation vessels.
120 dB sound volume.
3 selectable color group identification.
Input voltage can be selectable at the orders.
Multiple unit can be connecting.
Fully customized solutions can be design.


NAVIGATION LIGHT CONTROLER

Redundant power supply.
Customized gravur plate
Special design for tugboat and others.
Power failure and broken bulb alarm.
Audible and external contact output.
Input voltage can be selectable at the orders.
Current relay or PLC based solutions.
Suitable for case by case approvals.
Led indication.
Special naval system solutions.


GENERAL ALARM SYSTEM CONTROLER

Redundant power supply.
4 different sound style
Power failure.
Input voltage can be selectable at the orders.
Led indication.
PLC based system, can be configurable.
External Fire alert input.
External General alarm input.
External Talkback or Public address input.
Certified indoor and outdoor sounder 115 dB.
External Whistle output.
Alarm system output.


WHISTLE SYSTEM CONTROLLER

Redundant power supply.
External input for wing consoles.
Power failure.
Input voltage can be selectable at the orders.
Led indication.
PLC based system, can be configurable.
Fog tones according to Solas.
Timer selection according to solas.
Alarm system output.


EMERGENCY ENGINE TELEGRAPH SYSTEM

Redundant power supply.
Between units 2 core cable for reducing cabling costs.
Communication error signal.
Very easy installation ability.
Power failure alert.
Input voltage can be selectable at the orders.
Led indication.
PLC based system,
Modules consist of 2 or 3 unit (Wheel house, ECR, Engine Room)
Alarm system output.
Long testing experience.


AUTOMATIC VOLTAGE REGULATORS (AVR)

Flexible range current output (25A-75A-125A)
Suitable for parallel operations for generators.
Drop function.
Current transformer drop functions.
Suitable for 220 V, 380 V, 400 V and 440 V altenators.
Frequency level cannot be affecting to creation of voltage.
Ideal speed protections.
Fuse protection for output.
External voltage adjustment.