If you want your products to be like the first day, you should work with us.
Low and medium voltage AC / DC alternator and motor winding up to 3000kW,
Assistance service for dismantling the engine,
Error analysis,
Following up the process within the framework of ISO 9001 rules,
Receiving drawings for winding,
Disassembly of coil and insulation equipment,
Rewinding of bobbins,
Isolation of coils,
Mechanical control and rotor, stator, cover etc. troubleshooting,
Sand blasting the surface (optionally),
Surface painting (on request),
Performing voltage, current, insulation and vibration tests.
According to the fully automatic or manual needs of the project, low voltage panels up to 1000V, generator protections, load connected start-stop, load shedding, automatic synchronization, load sharing, dimming start, KVAR sharing. All this system is certified from breaker to cable tie.
Special designs are made for different combinations of generators.
If the ship console design is desired, it can be made personal or ship specific. 2 mm galvanized sheet is used. Device locations are easily accessible. A well-marked terminal has been designed and has interior lighting.
It is possible to choose alternatives from a large color scale. It has IP 22 protection class.
440/400V, 220/110V, 24V AC and DC sources. Covered and insulated connection equipment according to the class rules, known electrical products are used. Special designs are made for GMDSS systems.
Insulation and consumption and voltage indicators are available for 24 V cabinets.
For each control voltage level, whether within the class requirement or not, the certified controller with the VACON controller, climate control cabinets, is realized with low harmonic distortions.
With programmable user-friendly design, multi console panel design is made, suitable for dynamic position system. Models tested from 22kW to 100kW. Design is required for powers higher than 100kW. Only control system device can be provided.
SCADA systems can be designed according to requests.
Alarm monitoring systems under 500 gtn are designed. Fan monitoring systems are implemented for vessels carrying live fish. Control systems, valves, MSB, pumps and alarms are studied for yachts. Galvanized shielded I / O modules, distributed I / O modules, crane automation systems can be realized from 8 inputs to 624 inputs.
It includes core cable between two units, communication failure signal, power failure warning, modules 2 or 3 units alarm output system to reduce wiring costs, easy installation and testing experience. It is carried out as a special design for specially designed tugboats and other vessels. Power outage and broken bulb alarm,
Features such as audible contact output, input voltage can be selected when ordering. Current relay or PLC-based solutions can be produced, there is an LED indicator, there are special marine systems.
A flexible current output (25A-75A-125A) for generators is suitable for paralleling. Dropout function, current transformer dropout function, 400V, 440V, 380V,
Suitable for 220V systems. The frequency level does not affect the voltage generation. There are fuse protection and external voltage settings for the output.
Motors up to 690V voltage can be started with direct, star delta, soft starter, frequency converter and auto transformer with auto start or remote start command. Efficiency mode selection,
On-demand operation functions, optionally withdrawable chassis design, external and internal fault indication, remote control opportunities, high protection services for short circuit and overcurrent situations are available.
For lighting and shore connection purposes – up to 100kW – these systems have very little voltage drop effect, no need for extra cooling,
There is kiln dried varnish, the primary and secondary parts are completely insulated, different solutions can be produced according to customer needs.